Mode 1 Bench Test Results - Temperature < 15C

O2 Sensor Throttle Switch/Idle Switch Duty Cycle Duration
State Idle Cruise WOT (%)  
Open     65  
Open >--- --->   65>75>65 3 seconds
Open     65  
Open   >--- ---> 65  
Open     65  
Open   <--- ---< 65  
Open <--- ---<   65  
0.500     65  
0.500 >--- --->   65  
0.500     65  
0.500   >--- ---> 65  
0.500     65  
0.500   <--- ---< 65  
0.500 <--- ---<   65  
Legend: = Steady State condition
>------> = Transition
Open = open circuit (sensor disconnected, faulty, or cold)
Zero = Short to ground
0.500 = Volts from O2 sensor
Notes: Opening either the throttle switch or the microswitch produces the
temporary enrichment. Throttle Switch: "Cruise" is an open circuit.
"Idle" and "WOT" each produce a closed circuit to ground.

Mode 2

Mode 3

Back to Lambda Description